166 167
HMT337 Humidity and Temperature Transmitter with warmed probe
For high humidities
1234567891011121314151617181920212223
V
aisala HUMICAP® Humidity and Temperature Transmitte
r
HMT330
7
A
1
PRICE
1
Transmitter type
HMT337
7
$2,480
2
Cable length 2 m cable
S
dew point prob
e
5 m cable
T $160
10 m cable
U $370
3
Additional temperatur
e
No probe 0
probe 2 m cable 1 $160
5 m cable 2 $180
10 m cable 3 $220
4
Parameters Td+Tdf+x (dew point probe only) C
RH+T+Td+Tdf+a+x+Tw+ppm+pw+pws+h+d
T
D
5
Displa
y
No displa
y
0
Graphic display with keypad 1 $320
6
Power suppl
y
10...35 VDC , 24 VAC (HMT300PWS) 0
Galvanic isolation for outputs 10...35 VDC , 24 VAC (DcDc-1) 1 $80
Universal AC -power (100....240 VAC) (Power-1) 2 $200
Universal AC -power (100....240 VAC) + US power cord (Power-1 and 215991) 3 $210
External US AC-adapter (for LAN/WLAN interface in USA and Canada)
Not IP65 9
$60
7
Analog Output Signa
l
4... 20 mA 1
for Ch1&Ch2(&Ch3
)
0... 20 mA 2
0... 1 V 3
0... 5 V 4
0... 10 V 5
+ Serial interface RS232 or optional communication modul
e
Analog output signal
s
No 3rd analog outpu
t
A
for Ch1 , Ch2 and Ch3 RH (0... 100%RH) RH=relative humidity BBB
T (range: see below) T=temperature CCC
Td (-20...100°C) (-4...+212 °F) Td=dewpoint DDD
Tdf (-20...100°C) (-4...+212 °F) Tdf = dewpoint/ frost point temperature EEE
a (0...600g/m3) (0...262 gr/ft3)
a=absolute humidity
FFF
Tw (0...100°C) (+32...+212°F) Tw=wet bulb temperature GGG
x (0...500g/kg d.a) (0...3500gr/lb)
x=mixing ratio
HHH
h (-40...1500 kJ/kg) (-9.5...+652.6 Btu/lb)
h=enthalpy JJJ
ppm (0…5000)
(0…5000) ppm=parts per million KKK
pw (0…1000 hPa) (0…14.5psi)
pw=water vapor pressure
LLL
pws (0…1000 hPa) (0…14.5psi) pws=saturation water vapor pressure MMM
dT (-10...+50 °C) (14...+122 °F) dT=(temperature-dewpoint temperature) NNN
SPECIA
L
Define quantity Ch1:_______________ Ch2:________________ Optional Ch3:_____________
_
XXX
Define scale Ch1:_______________ Ch2:________________ Optional Ch3:_____________
_
8
Channel 1
9
Channel 2
10
Channel 3, choose A, if not needed
11
Analog output rang
e
No temperature outpu
t
A
for temperature -40...+180°C
(-40...+356°F)
E
Note: Choose Option A, Other: Specify range:___________________
_
X
if no T output is desired
12
Output units Metric 1
Non-metri
c
2
13
Option for module slot 1 No modul
e
0
Relay output (Relay-1) 1 $180
RS-485 serial interface (galvanically isolated) (RS485-1) 2 $160
LAN (Ethernet) interface + 2 m cable (RJ45) 4 $260
WLAN (Wireless Ethernet) interface + antenna
Not with universal AC power
5 $320
Data logger module 6 $350
14
Option for module slot
2
No modul
e
0
Relay output (Relay-1) 1 $180
3rd Analog output Choose also analog output signal for Ch3 (AOUT-1) 3 $160
Data logger module Not possible if the data logger module has already been chosen in item 11 6 $350
15
Cable bushing
s
Cable gland (for 8...11mm cable) (for 0.315...0.433 inch cable) (214728SP)
A
Conduit fitting for wire conduit (NPT1/2"
)
(214780SP) B
8-pole connector with 5m cable (not possible with Universal AC power option) (212142) C $60
8-pole counter connector equipped with screw terminals (not possible with Universal AC power option) D $60
16
Transmitter installation Standard wall mountin
g
0
Adapter plate (for replacing the HMP230's)
(214829)
1 $90
Pole installation kit
(215108)
2 $100
Pole installation kit with rain shield
(215109)
3 $110
DIN rail kit (215094)
4 $90
17
Humidity sensor typ
e
Composite senso
r
HUMICAP180
C
5
Composite sensor with chemical purg
e
HUMICAP180
C
6
Compsite senso
r
HUMICAP180R
C
D
Compsite sensor with chemical purg
e
HUMICAP180R
C
E
Composite sensor for fuel cell application
s
HUMICAP180R
C
F
18
Sensor protection PPS plastic grid & stainless steel netting (DRW010281SP)
A
Sintered stainless steel filter (HM47280SP) C
Stainless steel grid
(HM47453SP) D
Membrane SST filter for fuel cell applications F
19
Installation kit No ki
t
A
for probe Duct installation kit (RH) (210697) C $80
Swagelok NPT 1/2" (RH) (SWG12NPT12)
K
$60
Swagelok ISO 3/8" (RH) (SWG12ISO38) L $60
Duct installation kit (RH + T probes) (210697 & 215003) P $160
Swagelok NPT 1/2" + Swagelok NPT 1/8" (RH + T) (SWG6NPT18 & SWG12NPT12) Q $120
Swagelok ISO 3/8" + Swagelok ISO 3/8" (RH + T) (SWG6ISO18 & SWG12ISO18) R $120
Swagelok ISO 1/2"
(SWG12ISO12)
Y
$60
20
Operating manual No manual
A
languag
e
English
(M210566EN) B
21
PC Accessorie
s
No
A
Service cable for PC (19446ZZ) B
$40
MI70LINK software for Windows® with RS232 service cable (215005) C
$60
Service cable for PC, USB with software driver D
$90
MI70LINK software for Windows® with USB service cable
E
$90
22
Calibration ISO9001 compliant calibration with NIST traceable certificat
e
A
23
For future use 1
TOTAL
Selections in bold are included in the prices of the basic versions
.
QTY
Selections in italic are available at an extra price. TOTAL VALUE
Shaded sections indicate typical selections.
Example of order code with typical settings
:
HMT330 7 S 1 D 0 0 1 B C
A
E200
A
0D
A
A
B
A
A
1
(212416)
(219685)
(219916)
(214848)
HMT338 Humidity and Temperature Transmitter
For pressurized pipeline
s
1234567891011121314151617181920212223
Vaisala HUMICAP® Humidity and Temperature Transmitter HMT330 8 0 A 1 PRICE
1 Transmitter type HMT338 8 $1,980
2 Cable length 2 m cable for 232 mm probe V
5 m cable for 232 mm probe W
$160
10 m cable for 232 mm probe X
$370
2 m cable for 454 mm probe 1
$120
5 m cable for 454 mm probe 2
$260
10 m cable for 454 mm probe 3
$460
3 No additional temperature probe 0
4 Parameters RH+T A
RH+T+Td+Tdf+a+x+Tw+ppm+pw+pws+h+dT B
$360
5 Display No display 0
Graphic display with keypad 1 $320
6 Power supply 10...35 VDC , 24 VAC
(HMT300PWS)
0
Galvanic isolation for outputs 10...35 VDC , 24 VAC (DcDc-1) 1 $80
Universal AC -power (100....240 VAC) (Power-1) 2 $200
Universal AC -power (100....240 VAC) + US power cord (Power-1 and 215991) 3 $210
External US AC-adapter (for LAN/WLAN interface in USA and Canada)
Not IP65 9
$60
7 Analog Output Signal 4... 20 mA 1
for Ch1&Ch2(&Ch3) 0... 20 mA 2
0... 1 V 3
0... 5 V 4
0... 10 V 5
+ Serial interface RS232 or optional communication module
Analog output signals No 3rd analog output A
for Ch1 , Ch2 and Ch3 RH (0... 100%RH)
RH=relative humidity
BB
B
T (range: see below)
T=temperature
CC
C
Td (-20...100°C) (-4...+212 °F)
Td=dewpoint
DD
D
Tdf (-20...100°C) (-4...+212 °F)
Tdf = dewpoint/ frost point temperature
EE
E
a (0...600g/m3) (0...262 gr/ft3) a=absolute humidit
y
FF
F
Tw (0...100°C) (+32...+212°F)
Tw=wet bulb temperature
GG
G
x (0...500g/kg d.a) (0...3500gr/lb) x=mixing ratio HH
H
h (-40...1500 kJ/kg
)
(-9.5...+652.6 Btu/lb
)
h=enthalpy
JJ
J
ppm (0…5000
)
(0…5000)
ppm=parts per million
KK
K
pw (0…1000 hPa) (0…14.5psi) pw=water vapor pressure LL
L
pws (0…1000 hPa) (0…14.5psi)
pws=saturation water vapor pressure
MM
M
dT (-10...+50 °C) (14...+122 °F)
dT=(temperature-dewpoint temperature)
NN
N
SPECIAL Define quantity Ch1:_______________ Ch2:________________ Optional Ch3:______________ X X
X
Define scale Ch1:_______________ Ch2:________________ Optional Ch3:______________
8
Channel 1
9
Channel 2
10
Channel 3, choose A, if not needed
11 Analog output range No temperature output A
for temperature -40...+180°C (-40...+356°F) E
Note: Choose Option A,
Other: Specify range:____________________ X
if no T output is desired
12 Output units Metric 1
Non-metric 2
13 Option for module slot 1 No module 0
Relay output (Relay-1) 1 $180
RS-485 serial interface (galvanically isolated) (RS485-1) 2 $160
LAN (Ethernet) interface + 2 m cable (RJ45) 4 $260
WLAN (Wireless Ethernet) interface + antenna
Not with universal AC power
5 $320
Data logger module
6 $350
14 Option for module slot 2 No module 0
Relay output (Relay-1) 1 $180
3rd Analog output Choose also analog output signal for Ch3 (AOUT-1) 3 $160
Data logger module Not possible if the data logger module has already been chosen in item 11 6 $350
15 Cable bushings Cable gland (for 8...11mm cable) (for 0.315...0.433 inch cable)
(214728SP)
A
Conduit fitting for wire conduit (NPT1/2")
(214780SP)
B
8-pole connector with 5m cable (not possible with Universal AC power option) (212142) C $60
8-pole counter connector equipped with screw terminals (not possible with Universal AC power option) D $60
16 Transmitter installation Standard wall mounting 0
Adapter plate (for replacing the HMP230's)
(214829)
1 $90
Pole installation kit
(215108)
2 $100
DIN rail kit (215094)
4$90
17 Humidity sensor type General purpose HUMICAP180 1
Chemical purge
HUMICAP180C
4
$60
General purpose and high chemical concentrations HUMICAP180R A
Chemical purge
HUMICAP180RC C $60
18 Sensor protection
PPS plastic grid & stainless steel netting (DRW010281SP) A
PPS plastic grid (DRW010276SP) B
Sintered stainless steel filter (HM47280SP) C
Stainless steel grid
(HM47453SP)
D
19 Installation kit
Ball valve set (ISO 1/2") (DRW212076 + BALLVALVE-1) M $80
for probe Pressure fitting NPT 1/2"
(212810SP) N
Pressure fitting ISO 1/2" (DRW212076SP) V
20 Operating manual No manual A
language English (M210566EN) B
21 PC Accessories No PC Accessories A
Service cable for PC (19446ZZ) B
$40
MI70LINK software for Windows® with RS232 service cable (215005) C
$60
Service cable for PC, USB with software driver D
$90
MI70LINK software for Windows® with USB service cable
E
$90
22 Calibration ISO9001 compliant calibration with NIST traceable certificate A
23 For future use 1
TOTAL
Selections in bold are included in the prices of the basic versions.
QTY
Selections in italic are available at an extra price. TOTAL VALUE
Shaded sections indicate typical selections.
Example of order code with typical settings:
HMT3308V0A001BCAE200A0ACNBAA 1
Accessories: Description Order Code PRICE
Sample cell (no fittings) DMT242SC $80
Sample cell (with Swagelok connectors) DMT242SC2 $100
(212416)
(219685)
(219916)