Air Temperature and Relative Humidity Sensor
Periodic Maintenance
Calibration and maintenance of the air temperature and relative
humidity probe should be performed at regular intervals, depending on
the conditions of use and desired accuracy. The validity of the readings
should be checked annually.
The Air Temperature and Relative Humidity probes are easy to
maintain and calibrate. The sensor consists of a probe head and a handle
with cable. All calibration electronics are in the probe head, which can
be disconnected from the handle without disconnecting the wires, as
shown in Figure 144 on page 172. If you wish to continue the
measurement immediately, you can insert a calibrated probe head in
place of the disconnected one; this way the measurement is interrupted
for less than a minute.
0201-047
Figure 144 Probe Maintenance
The following numbers refer to Figure 144 on page 172.
1 = Adjustment trimmers: W = wet, D = dry, (T = temperature;
for factory use only)
2 = O-ring for sealing the probe weather tight