Chapter 6 ______________________________________________________________ Maintenance
VAISALA______________________________________________________________________ 169
0505-208
Figure 142 Replacing the PTU Module
Combined Wind Sensor
Periodic Maintenance
Testing Proper Operation
It is recommended to check the ball bearings of the anemometer and the
vane every year. If the cup wheel or the vane is not rotating smoothly or
it creates detectable noise, the bearings must be replaced.
Replacing Consumables
Only a trained technician should replace the bearings.
If your sensor includes the alignment sleeve and the factory alignment
has not been altered, you can simply remove and remount the sensor to
its place with the plastic collar without realigning.
To replace the ball bearings, do the following (the numbers refer to
Figure 143 on page 171):