Stopping Continuous Outputting
S
Use the S command to end the RUN mode. After this command all other
commands can be used. You can also press the Esc button or reset the
transmitter to stop the outputting.
See command SMODE to change the default (power-up) operation
mode.
Outputting Reading Once
SEND
Use the SEND command to output the reading once in STOP mode. The
output format depends on which parameters the transmitter can output.
Examples:
RH= 98.4 %RH T= 31.1 'C
RH= 98.4 %RH T= 31.1 'C Td= 36.0 'C Tdf= 36.0 'C a= 42.4
g/m3 x= 38.8 g/kg Tw= 30.8 'C ppm= 62414 pw= 59.53 hPa
pws= 60.52 hPa h= 130.7 kJ/kg
Outputting Reading with Raw Data
SEND D
Example:
>send d
24.1720 15.0399 -3.5743 189.2324 15.0709 15.0399
23.9765
Where the readings (from the left) are:
24.1720 = Temperature of the humidity probe ( ºC)
15.0399 = RH (%RH)
-3.5743 = Tdf (C)
189.2324 = Capacitance (pF)
15.0709 = RH raw: calculated from scaled capacitance (%RH)
15.0399 = Enhancement factor corrected RH (%RH)
23.9765 = Temperature of the additional temperature probe
(optional) (ºC)