Chapter 5 _________________________________________________________________ Operation
To start continuous measurement, use the START command.
You can stop the measurement with the STOP command. For
instructions, refer to START — Start Continuous Measurement
and STOP — Stop Wind Measurement on page 115.
WS425 A/B NMEA Extended
Commands
This command polls data from WMT700.
$WIP<id>Q,*<chk><CR><LF>
Checksum (8-bit XOR, excluding $ and *)
Carriage return code, ASCII 0DH
Line feed code, ASCII 0AH
Table 48 Checksum Table
NOTE
To use WMT700 with the NMEA Extended profile, either set the
autoSend
parameter to 0 to enable polling or define a fixed output
autoInt parameter. If you are using automatic messages,
autoSend parameter must be set to 15.
VAISALA _______________________________________________________________________ 157