User's Guide ______________________________________________________________________
Interpretation of the example message:
- Wind speed, average, x component: -0.04
- Wind speed, average, y component: 0.07
For examples of different wind speed and direction presentations,
see Figure 13 on page 39.
WMT700 Data Message 23
WMT700 Data Message 23 reports wind measurement and self-
diagnostics data in the format described below:
$\ws,\wd,\wp,\wm,\Ts,\vh,\vi,\ta,\er\cr\lf
Status code. The code is a decimal number. Each bit
corresponds to a status flag. For a list of the bits, see
section Status Flags on page 123
Example:
$03.21,75.83,03.34,03.15,22.37,12.2,23.5,20.0,32<cr><
lf>
Interpretation of the example message:
- Wind speed, average: 3.21 m/s
- Wind direction, average: 75.83°
- Wind speed, maximum: 3.34 m/s
- Wind speed, minimum: 3.15 m/s
- Sonic temperature: 22.37 °C
- Heater voltage: 12.2 V
- Supply voltage: 23.5 V
- Transducer temperature: 20.0 °C
- Status code: 32, which corresponds to status bit 5. For the
meaning of status flags, see section Status Flags on page 123
130 __________________________________________________________________ M211095EN-E
Komentarze do niniejszej Instrukcji