The available data by message type is as follows:
Lizard Variable Message Description
mass 1 Mass measurement from the
precipitation gauge in grams
operVoltage 1, 2 Supply voltage to the precipitation
gauge
prAccumulation 1 Precipitation accumulation in mm
prIntensity 1 Precipitation intensity in mm/h
statusData 1 Data status: 0 = Data OK, 1 =
Failure, 2 = Overflow, 3 = Draining
statusHeater 1 Heater status: 0 = Heater off,
1 = Heater on, 2 = Heater failure
statusHW 1 Precipitation gauge hardware
status: 0 = Hardware OK, 1 =
Failure, 2 = Warning
temperature 1 Temperature measurement from
Pt100 sensor; -99.99 = No sensor
temperatureCPU 1, 2 Temperature of the electronics
enclosure