104
GMM220 Carbon Dioxide Modules for
Demanding OEM Applications
For Harsh Environments
The Vaisala CARBOCAP
®
Carbon
Dioxide Module Series GMM220 are
designed for Original Equipment
Manufacturers (OEM’s) requiring
carbon dioxide measurements in
harsh and demanding applications.
Vaisala CARBOCAP®
The GMM220 series modules
incorporate the industrial Vaisala
CARBOCAP
®
Sensor. The patented
sensor has unique reference
measurement capabilities. Its critical
parts are made of silicon; this gives
the sensor outstanding stability over
both time and temperature.
Since water vapor, dust, and
most chemicals do not affect the
measurement, the GMM220 series
modules can be used in harsh and
humid environments.
The Vaisala CARBOCAP
®
Carbon Dioxide Module Series GMM220 withstand
harsh conditions. They provide high carbon dioxide measurement accuracy
over wide temperature and relative humidity ranges.
Interchangeable Probes
The GMP220 probes are
interchangeable. They can be
removed, reattached or replaced at
any time – without the need for
calibration and adjustment. The
interchangeable probes make
calibration and  eld service easy. In
addition, the measurement range can
be changed simply by replacing one
probe with another.
Di erent Confi gurations
The user has a choice of
measurement ranges up to 20 % CO
2
:
the Vaisala CARBOCAP
®
Carbon
Dioxide Module GMM221 for higher
and the Vaisala CARBOCAP
®
Carbon
Dioxide Module GMM222 for lower
concentrations of CO
2
.
Different power supply voltages,
output options, as well as cable
lengths, connectors, and mounting
gear are also available.
Features/Benefi ts
Incorporates Vaisala
CARBOCAP® - the silicon
based CO
2
sensor
Choice of several measurement
ranges
IP65 protected probe against
dust and spray water
Interchangeable probes
provide easy maintenance
Modules optimized for
integration into equipment for
greenhouse control, incubators,
fermentors, safety alarming
and integrated systems.
4-Carbon-Dioxide-Pages-100-119-Vaisala-Catalog-2011.indd 104 24.10.2011 9.21
105
Technical Data
For more information, visit
www.vaisala.com or contact
us at sales@vaisala.com
Ref. B210856EN-D ©Vaisala 2011
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifi cations — technical included — are subject
to change without notice.
Carbon Dioxide
Measurement ranges
GMM221 for high concentrations 0 ... 2 %, 0 ... 3 %, 0 ... 5 %,
0 ... 10 %, 0 ... 20 %
GMM222 for low concentrations 0 ... 2000 ppm, 0 ... 3000 ppm,
0 ... 5000 ppm, 0 ... 7000 ppm,
0 ... 10 000 ppm
Accuracy (including repeatability, non-linearity and calibration
uncertainty) at 25 °C and 1013 hPa
GMM221 ±(1.5% of range + 2% of reading)
(applies for concentrations above 2% of full scale)
GMM222 ±(1.5 % of range + 2 % of reading)
Temperature dependence, typical -0.3 % of reading / °C
Pressure dependence, typical +0.15% of reading hPa
Long-term stability <±5 %FS/2 years
Response time (63 %)
GMM221 20 seconds
GMM222 30 seconds
Warm-up time
30 seconds, 15 minutes
full specifi cations
Inputs and Outputs
Outputs 0 ... 20 or 4 ... 20 mA, 0 ... 1 V, 0 ... 2V,
0 ... 2.5 V, or 0 ... 5 V
Resolution of analog outputs 12 bits
Recommended external load:
current output max. 200 Ohm
voltage output min. 1 kOhm
Operating voltage 11 ... 20 VDC or 18 ... 30 VDC
Connections screw terminals, wire size 0.5 ... 1.5 mm
2
Power consumption <2.5 W
Operating Environment
Operating temperature -20 ... +60 °C (-4 ... +140 °F)
Storage temperature -30 ... +70 °C (-22 ... +158 °F)
Operating pressure 700 ... 1300 hPa
Humidity
probe 0 ... 100 %RH, non-condensing
mother board 0 ... 85 %RH, non-condensing
Electromagnetic compatibility EN61326-1, Generic Environment
Mechanics
Probe housing material PC plastic
Housing classifi cation (probe only) IP65
Weight: GMM221 (w/2m cable) max. 180 g
Weight: GMM222 (w/2m cable) max. 200 g
Probe cable length 0.6 m, 1 m (high temperature cable),
2 m, 6 m or 10 m (optional)
Accessories
Spare probe GMP221, GMP222
(use the order form to defi ne measurement range etc.)
Clips (2 pcs) for attaching the probe 25245GM
Mounting fl ange for the probe GM45156
CO
2
Calibration Unit GMK220
Probe cables
1 m high temperature probe cable
(180 °C / 365 °F) GMM220Z100SP
2 m probe cable GMM220Z200SP
6 m probe cable GMP343Z600SP
10.0 m probe cable GMP343Z1000SP
Serial COM adapter 19040GM
Dimensions
Dimensions in mm (inches)
GMP222GMP221
4-Carbon-Dioxide-Pages-100-119-Vaisala-Catalog-2011.indd 105 24.10.2011 9.21
Przeglądanie stron 106
1 2 ... 102 103 104 105 106 107 108 109 110 111 112 ... 161 162

Komentarze do niniejszej Instrukcji

Brak uwag